-40%

OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load

$ 17.32

Availability: 98 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: OMRON
  • Non-Domestic Product: No
  • Custom Bundle: No
  • All returns accepted: Returns Accepted
  • Condition: New
  • MPN: Does Not Apply
  • Model: SHL-Q2255
  • Modified Item: No
  • Item must be returned within: 60 Days
  • Return shipping will be paid by: Seller

    Description

    Welcome To Fibica
    Follow Daily Mart on:
    OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load
    Product Description
    OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load
    Availability:
    Customize
    Usually Ships within 2-4days
    Any Questions:
    Chat with a Specialist >
    Feel free to contact our specialist for any compatibiltiy problems.
    Close Notes
    Quantity:
    1
    Buy it Now
    If you have any questions, please inform us by eBay message.
    Close Notes
    Product Detail
    Why Daily Mart ?
    International Shipping
    Return & Warranty
    Product Specification:
    Shape / Structure
    Enclosed Limit switches
    service life
    General type
    Operating mechanism
    Snap action
    Actuator
    Panel mount roller plunger
    Frequency
    50/60 Hz
    Switching mechanism
    Self-reset mechanism
    Contact configuration
    Single-Pole, Double-Throw type
    Contact form
    SPDT
    Load
    General load
    Ratings (AC): Non-Inductive load
    Rated voltage: 125 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
    Rated voltage: 250 VAC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
    Rated voltage: 480 VAC, Resistive load: 2 A (NC) 2 A (NO)
    Ratings (AC): Inductive load
    Rated voltage: 125 VAC, Inductive load: 3 A (NC) 3 A (NO), Motor load: 2.5 A (NC) 2.5 A (NO)
    Rated voltage: 250 VAC, Inductive load: 2 A (NC) 2 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
    Ratings (DC): Non-Inductive load
    Rated voltage: 8 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
    Rated voltage: 14 VDC, Resistive load: 10 A (NC) 10 A (NO), Lamp load: 2 A (NC) 2 A (NO)
    Rated voltage: 30 VDC, Resistive load: 5 A (NC) 5 A (NO), Lamp load: 1.5 A (NC) 1.5 A (NO)
    Rated voltage: 125 VDC, Resistive load: 0.4 A (NC) 0.4 A (NO), Lamp load: 0.4 A (NC) 0.4 A (NO)
    Rated voltage: 250 VDC, Resistive load: 0.2 A (NC) 0.2 A (NO), Lamp load: 0.2 A (NC) 0.2 A (NO)
    Ratings (DC): Inductive load
    Rated voltage: 8 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
    Rated voltage: 14 VDC, Inductive load: 5 A (NC) 5 A (NO), Motor load: 2 A (NC) 2 A (NO)
    Rated voltage: 30 VDC, Inductive load: 1.5 A (NC) 1.5 A (NO), Motor load: 1.5 A (NC) 1.5 A (NO)
    Rated voltage: 125 VDC, Inductive load: 0.05 A (NC) 0.05 A (NO), Motor load: 0.05 A (NC) 0.05 A (NO)
    Rated voltage: 250 VDC, Inductive load: 0.03 A (NC) 0.03 A (NO), Motor load: 0.03 A (NC) 0.03 A (NO)
    Explanation
    The above values indicate the steady-state current. Lamp load has an inrush current of 10 times the steady-state current. Inductive load has a power factor of 0.4 Min. (AC) and a time constant of 7 ms Max. (DC). Motor load has an inrush current of 6 times the steady-state current.
    Inrush current
    NC: 15 A
    NO: 15 A
    Protective circuit
    Classification of protection against electric shock: Class II (Double insulation)
    Short-circuit protective device: 10 A fuse type gI or gG (IEC269)
    Ambient temperature
    Operating: -10 to 80 CEL
    (with no icing or condensation)
    Ambient humidity
    Operating: 35 to 95%RH
    (with no icing or condensation)
    Characteristics
    Permissible operating speed
    0.1 mm/s to 0.5 m/s
    Permissible operating frequency (Mechanically)
    120 operations / 1 minute Max.
    Permissible operating frequency (Electrically)
    30 operations / 1 minute Max.
    Contact resistance
    15 mOhm Max. (Initial value)
    (Measuring method is contact resistance meter.)
    Insulation resistance
    Between each terminal of the same polarities: 100 MOhm Min.
    Between live-metallic part and ground: 100 MOhm Min.
    Between each terminal and non-live-metallic part: 100 MOhm Min.
    (at 500 VDC Megger)
    Dielectric strength
    Between each terminal of the same polarities: 1,000 VAC
    Between live-metallic part and ground: 2,000 VAC
    Between each terminal and non-live-metallic part: 2,000 VAC
    (50/60 Hz for 1 min)
    Durability (Mechanically)
    10,000,000 operations Min. (No load)
    (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
    Durability (Electrically)
    500,000 operations Min. (Resistive load 10 A at 125 VAC)
    (Temperature, Humidity conditions: 5 CEL to 35 CEL, 40 %RH to 70 %RH)
    Pollution degree
    3 (EN60947-5-1)
    Vibration resistance (Malfunction)
    Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
    Shock resistance (Destruction)
    1,000 m/s2
    Shock resistance (Malfunction)
    Contact opening is 1 ms Max. at the free position and the total travel position at 300 m/s2.
    Degree of protection
    IEC60529 (JEM): IP67
    NEMA250: Type1
    Applicable standard (UL)
    Standard No.: UL508
    File number: E76675
    Applicable standard (CSA)
    Standard No.: C22.2 NO.14
    File number: LR45746
    Applicable standard (TUV)
    Standard No.: EN60947-5-1
    File number: J50062486
    Applicable standard (CCC(CQC))
    Standard No.: GB14048.5
    File number: 2003010305072162
    Applicable standard (EC Directive (Low Voltage Directive) )
    2006/95/EC
    Mounting specification
    Panel mounting, Side mounting
    Operating characteristics
    Operating Force (OF)
    Standard value 9.81 N Max.
    Release Force (RF)
    Standard value 1.96 N Min.
    Pre-Travel (PT)
    Standard value 1.5 mm Max.
    Over-Travel (OT)
    Standard value 2 mm Min.
    Movement Differential (MD)
    Standard value 0.5 mm Max.
    Operating Position (OP)
    Standard value 43 +/- 0.8 mm
    Package Include:
    1 x NEW OMRON SHL-Q2255 Panel Mount Roller Plunger For Standard Load6 months warranty
    60 days money back
    Life-time support.
    Our specialists will be with you during shopping and after-sell. Professional advise and any technical problem will be provided. We will respond any question within
    24-hour
    normally. Please allow longer time for weekend.
    Our logistic team will pack your order safely, make sure the item will be arrived perfectly. And then the parcels will be pass to courier. The total dispatched time will be around
    1-2 days
    .
    We focus on product quality, rather than packaging and marketing, in order to deliver the
    finest quality
    of product at a fraction cost. We believe that you would like to pay for the item cost except unnecessary costs.
    Our product team will keep the products
    up-to-date
    , which can allows you to purchase the latest and valuable products from our stores. We believe our
    Wide Product Range
    will be your selection.
    How should I make my payment ?
    We accept
    PayPal
    . Your payment is protected by
    Buyer Protection
    .
    Items will be shipped within
    1-2 working days
    of payment being made.
    No mailing payment will be accepted.