-40%
New Omron S8VS-01524 100-240VAC DIN Rail Power Supply 5V 2A Output 10W Switching
$ 30.2
- Description
- Size Guide
Description
New Omron S8VS-01524 100-240VAC DIN Rail Power Supply 5V 2A Output 10W SwitchingProduct Description:
Power rating
15 W
Efficiency
83 % TYP. (At 100 VAC input)
80 % TYP. (At 200 VAC input)
Rated input voltage
100 to 240 VAC
Allowable-input voltage variable range
85 to 264 VAC
80 to 370 VDC
Note at DC input
The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency
50/60 Hz (47 to 450 Hz Single-phase)
Rated input current
0.34 A TYP. (At 100 VAC input)
0.22 A TYP. (At 200 VAC input)
Harmonic Current
EN61000-3-2
Leakage current
0.5 mA Max. (At 100 VAC input)
1.0 mA Max. (At 200 VAC input)
Inrush current
14 A TYP. (At 100 VAC input (For cold start at 25 CEL))
28 A TYP. (At 200 VAC input (For cold start at 25 CEL))
Output voltage
24 VDC
Output voltage variable range
-10 to +15 % (With V. ADJ)
(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple
2 %(p-p) Max. (Under the rated I/O conditions.)
60 mV Max. (Under the rated I/O conditions.)
Static input variation influence
0.5% Max. (At 85 to 264 VAC input, 100% load)
Static load variation influence
1.5% Max. (Output voltage: 24 V, at rated input, 0 to 100% load)
Ambient temperature variation influence
0.05 %/CEL Max.
Rated output current
0.65 A
Start up time
600 ms TYP. (100 VAC input)
400 ms TYP. (200 VAC input)
Hold time
28 ms TYP. (100 VAC input)
134 ms TYP. (200 VAC input)
Overload protection
105% to 160% of the rated output current
Inverted L voltage drop, Intermittent operation, Automatic reset
Overvoltage protection
Operated at 130% Min. of the rated output voltage, Shut-off
Resetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection
No
Maintenance forecast monitor output
No
Total run time monitor output
No
Undervoltage alarm output
No
Power failure alarm output
No
Parallel operation
No (However, backup operation is possible; external diodes required.)
Series operation
Yes (Up to 2 Power Supplies with external diode)
Remote sensing function
No
Applicable standard (UL)
Standard No.: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
Applicable standard (CSA)
Standard No.: cUL: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
Applicable standard (EN)
EN50178, EN60950-1
Applicable standard (EC Directive (EMC Directive) )
Emission Enclosure: Conforms to EN61204-3 Class B
Emission AC mains: Conforms to EN61204-3 Class B and based on FCC Class A
Harmonic Current: EN61000-3-2
EMS: EN61204-3 Class B
Applicable standard (VDE)
VDE0160, VDE0805 Teil 1
Applicable standard (SEMI)
F47-0200 (200 VAC input)
Ambient temperature
Operating: -10 to 60 ℃
Storage: -25 to 65 ℃
(with no icing or condensation)
Ambient humidity
Operating: 25 to 85% RH
Storage: 25 to 90% RH
(with no icing or condensation)
Dielectric strength
Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)
Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)
Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Insulation resistance
Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance
10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance
150 m/s**2, in each 6 directions 3 times
Output indicator
Yes (color: green)
Heat radiation
Natural air-cooling
Construction
Covered type
Terminal type
Screw terminal
Mounting type
DIN Rail mounting type
Weight (Main)
Approx. 160 g
Package Include:
1 x New Omron S8VS-01524 100-240VAC DIN Rail Power Supply 5V 2A Output 10W Switching