    Power rating
    15 W
    Efficiency
    83 % TYP. (At 100 VAC input)
    80 % TYP. (At 200 VAC input)
    Rated input voltage
    100 to 240 VAC
    Allowable-input voltage variable range
    85 to 264 VAC
    80 to 370 VDC
    Note at DC input
    The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
    Frequency
    50/60 Hz (47 to 450 Hz Single-phase)
    Rated input current
    0.34 A TYP. (At 100 VAC input)
    0.22 A TYP. (At 200 VAC input)
    Harmonic Current
    EN61000-3-2
    Leakage current
    0.5 mA Max. (At 100 VAC input)
    1.0 mA Max. (At 200 VAC input)
    Inrush current
    14 A TYP. (At 100 VAC input (For cold start at 25 CEL))
    28 A TYP. (At 200 VAC input (For cold start at 25 CEL))
    Output voltage
    24 VDC
    Output voltage variable range
    -10 to +15 % (With V. ADJ)
    (The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
    Ripple
    2 %(p-p) Max. (Under the rated I/O conditions.)
    60 mV Max. (Under the rated I/O conditions.)
    Static input variation influence
    0.5% Max. (At 85 to 264 VAC input, 100% load)
    Static load variation influence
    1.5% Max. (Output voltage: 24 V, at rated input, 0 to 100% load)
    Ambient temperature variation influence
    0.05 %/CEL Max.
    Rated output current
    0.65 A
    Start up time
    600 ms TYP. (100 VAC input)
    400 ms TYP. (200 VAC input)
    Hold time
    28 ms TYP. (100 VAC input)
    134 ms TYP. (200 VAC input)
    Overload protection
    105% to 160% of the rated output current
    Inverted L voltage drop, Intermittent operation, Automatic reset
    Overvoltage protection
    Operated at 130% Min. of the rated output voltage, Shut-off
    Resetting: Reset the power by turning it back (OFF time: at least 3 min)
    Overheat protection
    No
    Maintenance forecast monitor output
    No
    Total run time monitor output
    No
    Undervoltage alarm output
    No
    Power failure alarm output
    No
    Parallel operation
    No (However, backup operation is possible; external diodes required.)
    Series operation
    Yes (Up to 2 Power Supplies with external diode)
    Remote sensing function
    No
    Applicable standard (UL)
    Standard No.: UL508 (Listing, Class 2: Per UL1310), UL UR: UL60950-1 (Recognition)
    Applicable standard (CSA)
    Standard No.: cUL: CSA C22.2 No.107.1 (Class 2: Per No.223), cUR: CSA C22.2 No.60950-1
    Applicable standard (EN)
    EN50178, EN60950-1
    Applicable standard (EC Directive (EMC Directive) )
    Emission Enclosure: Conforms to EN61204-3 Class B
    Emission AC mains: Conforms to EN61204-3 Class B and based on FCC Class A
    Harmonic Current: EN61000-3-2
    EMS: EN61204-3 Class B
    Applicable standard (VDE)
    VDE0160, VDE0805 Teil 1
    Applicable standard (SEMI)
    F47-0200 (200 VAC input)
    Ambient temperature
    Operating: -10 to 60 ℃
    Storage: -25 to 65 ℃
    (with no icing or condensation)
    Ambient humidity
    Operating: 25 to 85% RH
    Storage: 25 to 90% RH
    (with no icing or condensation)
    Dielectric strength
    Between all inputs and all outputs: 3 kVAC for 1 min (Detection current: 20 mA)
    Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)
    Between all outputs and PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
    Insulation resistance
    Between all outputs and all inputs/ PE terminals: 100 MOhm Min. (at 500 VDC)
    Vibration resistance
    10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
    Shock resistance
    150 m/s**2, in each 6 directions 3 times
    Output indicator
    Yes (color: green)
    Heat radiation
    Natural air-cooling
    Construction
    Covered type
    Terminal type
    Screw terminal
    Mounting type
    DIN Rail mounting type
    Weight (Main)
    Approx. 160 g
    Package Include: